  1. Path: mongol.sasknet.sk.ca!news@mongol.sasknet.sk.ca
  2. From: Dave.Keith@Develcon.Com (Dave Keith)
  3. Newsgroups: comp.dcom.cabling,comp.dcom.frame-relay,comp.dcom.modems
  4. Subject: Re: Standard pinout for V.35 in DB25 connector?
  5. Date: 29 Jan 1996 14:23:35 GMT
  6. Organization: Develcon Electronics Ltd.
  7. Message-ID: <4eil97$f2l@mongol.sasknet.sk.ca>
  8. References: <3109BD3F.1CA7@microplex.com> <1996Jan28.020322.1@eisner.decus.org> <4efvat$ce8@clarknet.clark.net>
  9. NNTP-Posting-Host: davek.develcon.com
  10. Mime-Version: 1.0
  11. X-Newsreader: WinVN 0.99.2
  12.  
  13. In article <4efvat$ce8@clarknet.clark.net>, blckshaw@clark.net says...
  14. >
  15. >In article <1996Jan28.020322.1@eisner.decus.org>, bruce@eisner.decus.org 
  16. >writes...
  17. >>
  18. >>In article <3109BD3F.1CA7@microplex.com>, Fred Fierling <fff@microplex.com> 
  19. >writ
  20. >>es:
  21. >>> A lot of modern WAN equipment comes equipped with V.35 implemented
  22. >>> on a DB25 connector.  Is there a standard pinout for V.35 on a
  23. >>> DB25 connector, de facto or otherwise?
  24. >>
  25. >>Are you sure you are seeing v.35 (as in the way Digital Link for one does
  26. >>it), or do you mean EIA-530 which is becoming more common but is 449 on a 
  27. >db25
  28. >>connector?
  29. >
  30. >He is probably looking at a video telecon system. Due to real estate
  31. >restrictions many vendors of VTC bring the V.35 interface out on a
  32. >DB-25 connector (I know of at least three who do this). Also V.35
  33. >interface cards for PCs simply do not have room for a true V.35
  34. >connector. All of the systems I've tested had adapter cables with
  35. >DB-25 (or similar) on one end and V.35 connectors on the other. I
  36. >don't recall the vendors putting any pinout diagrams in their
  37. >manuals and I would suspect that it is everyman for himslef.
  38.  
  39. In direct response to the original question,  there are no 'standards'
  40. for a V.35 interface pinned-out on a DB25.  It is very common on all
  41. types of serial equipment,  but everyone seems to do it a bit differently.
  42. Yes,  one of the reasons for using DB25s instead of Winchesters is size,
  43. but another is cost.  Those big blocks are darned expensive.
  44.  
  45. A few points on other comments.  Many vendors do supply a conversion cable,
  46. or make it available separately.  Unlike Bob,  virtually all of the equipment
  47. that I have seen with V.35 via DB25 provide the pinout in an Appendix to
  48. the manual.  In those cases where it is not in the manual,  a quick call to
  49. the vendor will get you the info,  and push that particular vendor one step
  50. closer to putting the info where it belongs.